In CODESYS version 3.5 SP17 and higher, the J1939 configurator is no longer supplied with a parameter group / signal database. The old database is no longer supported.
However, you can post-install a DBC database in the J1939 Manager. A database can be purchased, for example from CSS Electronics: ⮫ https://www.csselectronics.com/screen/product/j1939-dbc-file-pgn-spn
If you do not install a database, then you can also configure parameter groups and signals manually on the “User-Defined” tab.
CODESYS shows all parameters of the database on this tab. |
|
“Find” |
String for filtering the PGN list |
“Reset” |
Reset the filter for showing the full list |
“Filter” |
Only PGs of the selected type are shown. |
“Add PG” |
Adds the selected parameter group to the TX signal list. Multiple selection of parameter groups is possible. |
On this tab, you can created user-defined parameter groups. |
|
“PGN (18 Bit)” |
Unique number of the PG (0...262143) that is calculated from the four subsequent parameters. You can type in this value directly into the field. |
“PDU specific (bit 0–7)” |
Evaluation of the value depends on the value in “PDU format”.
|
“PDU format (bit 8-15)” |
Protocol Data Unit The format determines whether the message can be transmitted with a target address or always as a broadcast message. |
“Data page (bit 16)” |
Selection of the page for the PDU format (currently always |
“Expanded data page (bit 17)” |
Not used: For future expansion. |
“Name” |
Name of the new parameter group. |
“Length (bytes)” |
Length of the parameter group (in bytes) |
“Priority” |
Priority of the parameter group (0..7). Priority 0 is the highest and 7 is the lowest. |
“Description” |
Description of the parameter group |