Function: This command opens the “Trace Statistics” dialog box, which shows statistics about each trace variable.
Call: Main menu “Trace”, or right-click.
Requirement: The trace editor contains samples.
Dialog Box 'Trace Statistics'
The analyzed time range and duration are shown in the caption.
The table contains one line per signal.
“Signal” |
Name pf the trace variable (for example, |
“Index” |
0-based index of the signal order |
“N” |
Number of measurements for the calculations |
“Min” |
Smallest value |
“Avg” |
Average |
“Median” |
Middle value when the values are ordered by size |
“RMS” |
Root mean square |
“StdDev” |
Standard deviation |
“Max” |
Largest value |
“Integral” |
Integral |
“Min Δt [s]” |
Smallest change of time intervals for successive values |
“Avg Δt [s]” |
Average change of time intervals for successive values |
“Median Δt [s]” |
Median change of time intervals for successive values |
“StdDev Δt [s]” |
Standard deviation of change of time intervals for successive values |
“Max Δt [s]” |
Largest change of time intervals for successive values |
Click a column head in the table. |
CODESYS sorts the table by that column, changing the order from ascending to descending and back. Default: The table is sorted ascending by the “Index” column. The signals are then sorted in the same order as in the signal tree. |
Click in the line. |
The line is selected. You can select or clear other lines by pressing [Shift]+[arrow] up or down. |
[Ctrl]+[C] |
CODESYS copies the selected lines as text to the clipboard. The values of the individual columns are tab-separated, and the lines are delimited with the control character [CR] or [LF]. Requirement: At least one line is selected. |
See also